Quick Overview

Material: Cement Bound Matrix Board (CBM)
Thickness: 18 mm
Sizes: 650 x 2700 mm
Colours: Grey
Application: Structural flooring
Brochure: System Floor PDF

This construction provides higher Flexural and Tensile strength compared to a standard 18mm thick board. One face smooth and one face textured, ready to form a finished surface able to receive many forms of floor finish treatment.
SystemFLOOR is resistant to the effects of moisture and will not physically deteriorate when used in damp or humid conditions. Performance characteristics are not degraded by age or moisture.
Fast and easy to install, SystemFLOOR is manufactured to meet environmental standards.

Features and Benefits:

  • Impermeable to water
  • Rot resistant
  • Termite resistant
  • Heavy duty
  • High flexural strength
  • High tensile strength
  • Excellent durability
  • Lightweight
  • Lapped joint
  • Fixing board to board
  • Time saving installation
  • Good thermal insulation
  • Improved acoustic insulation values
  • Non-combustible and Class 0 building material, in accordance with BS 476: Parts 4, 6 and 7
  • Asbestos free and non hazardous

Assembly Process

sf-fixing-staple
sf adhesive-joist
sf adhesive-board
sf-fixing-screw

Technical

Product generic description Cement Bound Matrix board
Non Combustible EN ISO 1182:2002
BS 476: Part 4
Building regulations classification Class 0 (BS 476: Parts 6 & 7)
Heat and smoke release rates (tested to AS/NZS 3837) Group 1
Spread of flame for bare floor (tested to AS ISO 9239: Part 1)) Passed
Thermal conductivity (approximate) at 20C 0.166
Simultaneous determination of ignitability, flame flame propagation, heat and smoke release
(tested to AS 1530: Part 3)
Determination of ignitability: 0
Determination of flame propagation: 0
Determination of heat release: 0
Determination of smoke developed: 0-1
Water permeability (tested to AS 2908: Part 2: 2000) Passed
Water proof (tested to AS 3740: 2004 using wet area membrane) Impermeable to water
Water tightness to BS 4624: 1981 Passed
Alkalinity (approximate) pH 9 -10
Typical moisture content
(ambient to dry condition, tested to BS 5669: Part 1, Clause 9)
1.5%
Uniformly Distributed Loads
(in accordance with AS/NZS 1170: Part 1 up to 20kPa)
Passed
Concentrated loads on joists spaced at 450mm centres
(single layer of board 18mm thick)
In accordance with AS/NZS 1170: Part 1
Using 0.01m2 diameter applicator kN
Using 350mm2 applicator (punch test) kN
Maximum concentrated load
5.92
2.46
Concentrated loads on joists spaced at 450mm centres
(single layer of board 18mm thick)
In accordance with AS/NZS 1170.1
Using 0.01m2 diameter applicator kN
Using 350mm2 applicator (punch test) kN
Maximum concentrated load
6.07
3.0

Mildew Growth (no visible growth of Mildew in accordance with HN 0028)
Passed
Acoustic (One hour fire resistant floor system)
Airborne
Impact
Rw+Ctr 52
LnW + Ci 56
Complying with most residential requirements.
Density (tested to BS 5669: Part 1: 1989, Clause 8) kg/m3 Nominal 1100
Emission test (to ASTM D5116-90 for Green Label Singapore) Within limits set out by the Singapore Environment Council
Steel and timber joists centres 450mm centres
Thickness tolerance of standard boards mm ± 0.5 for board thickness ≤ 15
± 1.0 for board thickness > 15
Length x width tolerance of standard boards mm ± 1
Surface condition Smooth and fair face on both sides

For more information, please download pdf files.